Search results for "solutions for peritoneal dialysis"

showing 3 items of 3 documents

Study of biocompatibility of peritoneal dialysis solutions measured as in vitro cells viability

2019

This paper presents the comparable viability study results of the HepG2 and Vero cells in the presence of traditional peritoneal dialysis (PD) solutions determined by three methods (3-[4,5-dimethylthiazol]-2-yl-2,5-diphenyl tetrazolium bromide (MTT), neutral red (NR) and sulforhodamine B assays) with establishing different correlations between viability and quality indexes of the tested PD solutions. The obtained results confirmed cytotoxicity of the PD solutions even compared with an isotonic solution of sodium chloride. PD solutions action resulted in a similar reduction in the HepG2 and Vero cells. Moreover, this research found that metabolic cellular activity is more vulnerable to the a…

MTTHepG2solutions for peritoneal dialysisviabilitysulforhodamine BVero cellsneutral redCeska a Slovenska Farmacie
researchProduct

Biological and analytical studies of peritoneal dialysis solutions

2018

The purpose of our work was to conduct biological and analytical studies of the peritoneal dialysis (PD) solutions containing glucose and sodium lactate and establish correlations between cell viability of the Vero cell line and values of analytical indexes of the tested solutions. The results of this study confirm the cytotoxicity of the PD solutions even compared with the isotonic solution of sodium chloride, which may be due to the low pH of the solutions, presence of glucose degradation products (GDPs) and high osmolarity of the solutions, and unphysiological concentrations of glucose and sodium lactate. However, it is not yet known what factors or their combination and to what extent c…

MTTsolutions for peritoneal dialysiskidney cells (Vero line)neutral redcell viabilityUkrainian biochemical journal
researchProduct

Approach of the State Pharmacopeia of Ukraine to analytical procedures validation on the example of chloride ions assay in peritoneal dialysis soluti…

2019

The objective of this study was to develop and validate an alternative analytical procedure for the total chloride assay in solutions for peritoneal dialysis (PD). The proposed analytical procedure was validated according to the requirements of the International Conference on Harmonization (ICH) Guideline: Topic ICH Q2(R1) and the approach of the State Pharmacopeia of Ukraine (SPU). The analytical procedure was specific. The li-nearity of the procedure was evaluated in the concentration range of 76 to 114 mmol/L of chloride ions (80-120% of the stated content (95 mmol/L)) with the regression equation y = 1.0029 ∑ X -0.2269 and a correlation coefficient of 0.9989. The y-intercept of the regr…

Pharmacologyvalidationsolutions for peritoneal dialysisChromatographybusiness.industryPharmaceutical Sciencechlorides assayChlorideIonargentometric methodmedicineAnalytical proceduresPeritoneal dialysis solutionsbusinessuncertaintymedicine.drugActa Poloniae Pharmaceutica
researchProduct